Personal tools
You are here: Home / Implementation / IFC2x3 impl guidance / IFC Impl Agreements / #CV-2x3-133

#CV-2x3-133

Restrict the insertion point of doors and windows in regard to the opening.
number
CV-06-133
based on
IFC2x3
effects
extended coordination view
date
24. Nov 2006
initiator
ISG meeting in Dijon
summary Restrict the insertion point of doors and windows in regard to the opening

 

Description

Doors an windows inserted into an opening should follow an agreement about positioning. The proposal is:

  • Doors and windows shall have a local placement, the local placement shall be relative to the opening into which they are inserted.
  • Doors and window should be located inside the first quadrant of the local placement with the insertion point of the door aor window at the origin.
  • The insertion point of the door andwindow is defined to be the lower-left-bottom corner of the door and window panel.

 

The following figures show correct placements of doors inside a wall.

 

#CV-2x3-133-1

 

Fig 1: insertion of doors inside the wall

 

#CV-2x3-133-2

 

Fig 2: insertion of doors inside walls

 

#CV-2x3-133-3

 

Fig 3: insertion of doors inside walls